How Can We Help?
KCN-A*SR-* replace
Question
I would like to replace KCN-A*SR-*.
Please tell me the successor model and update procedure when updating to the current product.
Answer
The successor model will be the KCV series.
Since there are differences in specifications, please check the following notes when replacing.
Replace
Model number comparison table
KCN-A series | KCV series | Remarks |
---|---|---|
KCN-A4SR | KCV-4S | 4-digit AC power contact output |
KCN-A6SR | KCV-6S | 6-digit AC power contact output |
KCN-A4SR-C | KCV-4S-C | 4-digit DC power supply contact output |
KCN-A6SR-C | KCV-6S-C | 6-digit DC power supply contact output |
Notes
1. The maximum input speed is different. (KCN-A:5kHz -> KCV:10kHz)
2. The terminal block arrangement and setup menu items / display order are different between KCN-A and KCV.
3. The key protection method is different.
4. KCV will not output, if the set value is 0.
5. The depth dimension of the product is different. (AC power supply: + 10mm, DC power supply: + 5mm)
6. Set the KCV with prediction output setting to “zero”.
2. The terminal block arrangement and setup menu items / display order are different between KCN-A and KCV.
3. The key protection method is different.
4. KCV will not output, if the set value is 0.
5. The depth dimension of the product is different. (AC power supply: + 10mm, DC power supply: + 5mm)
6. Set the KCV with prediction output setting to “zero”.
About operation
Input mode | Replaceability |
---|---|
Addition mode | Available |
Subtraction mode | Available |
Output mode | Replaceability |
---|---|
Holding output | Available |
One-shot output | Available |
Coincidence output | Available |
Input connection method
Output connection method
Key protection settings
KCN-A series | KCV series |
---|---|
Short-circuit terminal blocks 5 and 6 | Set with SW6 |
Preset value
Both KCN-A / KCV are set with each digit key.
DIP switch setting
Settings in Setup Mode
The setting order of the setup mode menu is different between KCN-A and KCV.
In addition, some functions have changed to DIP SW settings.
For set-up, please refer to the figure below.
In addition, some functions have changed to DIP SW settings.
For set-up, please refer to the figure below.
Inquiry
technical support
Click here for inquiries by email
Click here for inquiries by email