How Can We Help?
KCN-4SR-* replace the timer operation
Question
I would like to replace the KCN-4SR-* used for timer operation.
Please tell me the successor model and update procedure when updating to the current product.
Answer
The successor model will be the KT-V series.
Since there are differences in specifications, please check the following notes when replacing.
Replace
Model number comparison table
KCN-S series | KT-V series | Remarks |
---|---|---|
KCN-4SR | KT-V4S | 4-digit AC power contact output |
KCN-4SR-C | KT-V4S-C | 4-digit DC power supply contact output |
Notes
1. The terminal block arrangement and setup menu items / display order are different between KCN-S and KT-V.
2. The key protection method is different.
3. The depth dimension of the product is different. (AC power supply: + 10mm, DC power supply: + 5mm)
4. Set the prediction output setting of KT-V to “zero”.
2. The key protection method is different.
3. The depth dimension of the product is different. (AC power supply: + 10mm, DC power supply: + 5mm)
4. Set the prediction output setting of KT-V to “zero”.
About operation
Output operation mode | Replaceability |
---|---|
Mode A: signal on-delay | Available |
Mode B: signal off-delay | Available |
Mode C: one shot | Available |
Mode D: signal flicker | Available |
Mode E: integration | Available |
Input connection method
Output connection method
Preset value
KCN-Both S / KT-V are set with each digit key.
Settings in setup mode
The setting order of the setup mode menu is different between KCN-S and KT-V.
In addition, some functions have changed to DIP SW settings.
Please set up referring to the figure below.
– In case of mode D –
– For modes A / B / C / E –
In addition, some functions have changed to DIP SW settings.
Please set up referring to the figure below.
– In case of mode D –
– For modes A / B / C / E –