KCN-*WR-* replace the single-preset setting

Question

Question

I would like to replace the KCN-*WR-* used in the single-preset setting.
Please tell me the successor model and update procedure when updating to the current product.

Answer

Answer

The successor model will be the KCV series.
However, there are some operation modes that cannot be replaced.
Since there are differences in specifications, please check the following notes when replacing.

Replace

Model number comparison table

KCN-W series KCV series Remarks
KCN-4WR KCV-4S 4-digit AC power contact output
KCN-6WR KCV-6S 6-digit AC power contact output
KCN-4WR-C KCV-4S-C 4-digit DC power supply contact output
KCN-6WR-C KCV-6S-C 6-digit DC power supply contact output

Notes

1. The maximum input speed is different. (KCN-W:5kHz -> KCV:10kHz)
2. The terminal block arrangement and setup menu items / display order are different between KCN-W and KCV.
3. The key protection method is different.
4. KCV will not output, if the set value is 0.
5. The depth dimension of the product is different. (AC power supply: + 10mm, DC power supply: + 5mm)
6. Set the KCV with prediction output setting to “zero”.

About operation

Mode OUT2 Replaceability
1 retentive output / count continuation Available
2 one-shot output / count reseting Available
3 one-shot output / count continuation Available
4 retentive output / count retention Unavailable
7 counting value <= SET2 Unavailable
8 SET1 <= counting value <= SET2 Unavailable

Input connection method

counter-18-1

Output connection method

counter-18-2

Preset value

Both KCN-W / KCV are set with each digit key.

Settings in setup mode

The setting order of the setup mode menu is different between KCN-W and KCV.
In addition, some functions have changed to DIP SW settings.
Please set up referring to the figure below.
counter-18-3