How Can We Help?
KCN-*WT-* replace the single-preset setting
Question
I would like to replace the KCN-*WT-* used in the single-preset setting.
Please tell me the successor model and update procedure when updating to the current product.
Answer
The successor model will be the KCV series.
However, there are some operation modes that cannot be replaced.
Since there are differences in specifications, please check the following notes when replacing.
Replace
Model number comparison table
KCN-W series | KCV series | Remarks |
---|---|---|
KCN-4WT | KCV-4S | 4-digit AC power non-contact output |
KCN-6WT | KCV-6S | 6-digit AC power non-contact output |
KCN-4WT-C | KCV-4S-C | 4-digit DC power supply non-contact output |
KCN-6WT-C | KCV-6S-C | 6-digit DC power supply non-contact output |
Notes
1. The maximum input speed is different. (KCN-W:5kHz -> KCV:10kHz)
2. The terminal block arrangement and setup menu items / display order are different between KCN-W and KCV.
3. The key protection method is different.
4. KCV will not output, if the set value is 0.
5. The depth dimension of the product is different. (AC power supply: + 10mm, DC power supply: + 5mm)
6. Set the KCV with prediction output setting to “zero”.
2. The terminal block arrangement and setup menu items / display order are different between KCN-W and KCV.
3. The key protection method is different.
4. KCV will not output, if the set value is 0.
5. The depth dimension of the product is different. (AC power supply: + 10mm, DC power supply: + 5mm)
6. Set the KCV with prediction output setting to “zero”.
About operation
Mode | OUT2 | Replaceability |
---|---|---|
1 | retentive output / count continuation | Available |
2 | one-shot output / count reseting | Available |
3 | one-shot output / count continuation | Unavailable |
4 | retentive output / count retention | Unavailable |
7 | counting value <= SET2 | Unavailable |
8 | SET1 <= counting value <= SET2 | Unavailable |
Input connection method
Output connection method
Preset value
Both KCN-W / KCV are set with each digit key.
Settings in setup mode
The setting order of the setup mode menu is different between KCN-W and KCV.
In addition, some functions have changed to DIP SW settings.
Please set up referring to the figure below.
In addition, some functions have changed to DIP SW settings.
Please set up referring to the figure below.