Question

Question

I am continuously using KCX-B* (KCX-B*M).
I heard that it will be discontinued, which is the alternative model?

Answer

Answer

A similar model is the KCV series.
Since there are differences in specifications, please check the following notes when replacing.
-Notes-
If used under the following conditions, it can be replaced with KCX-*D (KCX-*DM).
– Input logic: Positive logic (SW4 B side)
– Output operation switching: Mode 0 to 5 (SW5)
– When counting only in one direction (only adding, only subtracting)
-> Click here for details.

Replacement

Model number comparison table

KCX-B series KCV series remarks
KCX-B4 KCV-4S 4-digit AC power supply
KCX-B4M
KCX-B6 KCV-6S 6-digit AC power supply
KCX-B6M

Notes

1. External dimensions are different. (KCX: 72mm square -> KCV: 48mm square)
2. The maximum input speed is different. (KCX-B: 20kHz -> KCV: 10kHz)
3. The output current of the power supply for the sensor is different. (KCX: 80mA -> KCV: 60mA)
4. The KCV transistor output cannot be used in positive logic (PNP).
5. The terminal block arrangement and setup method are different between KCX-B and KCV.
6. Set the prediction output setting of KCV to “zero”.

About operation

Operation Mode Output Counting Replaceability
0 and 3 Holding Continuous Available
1 and 4 One-shot Continuous Unavailable
2 and 5 One-shot Reset Available
6 and 9 Count value is greater than the set value Unavailable
7 Count value is 0 or more and less than the set value Unavailable
8 Count value is minus Unavailable

Input connection method

counter-22-1

Output connection method

counter-22-2

Preset value

Both KCX-B / KCV are set with each digit key.

DIP switch setting

counter-22-3
When replacing modes 0 and 3 (hold output / count continuous), SW5 of KCV is set to ON.
When replacing modes 2 and 5 (one-shot output / count reset), set SW5 of KCV to OFF.
KCX-B* Dip SW4 (input / output logic) settings are set in the KCV setup mode.
* The transistor output of KCV cannot be used in positive logic (PNP).

Settings in setup mode