KCX-B*W(M) replace

Question

Question

I am continuously using KCX-B*W (KCX-B*WM).
I heard that it will be discountinued, which is the alternative model?

Answer

Answer

A similar model is the KCV series.
Since there are differences in specifications, please check the following notes when replacing.
-Notes-
If used under the following conditions, it can be replaced with KCX-*W (KCX-*WM).
– Input logic: Positive logic (SW4 B side)
– Output operation switching: Mode 0 or 2 (SW5)
– When counting only in one direction (only adding, only subtracting)
-> Click here for details.

Replacement

Model number comparison table

KCX-B series KCV series remarks
KCX-B4W KCV-4S 4-digit AC power supply
KCX-B4WM
KCX-B6W KCV-6S 6-digit AC power supply
KCX-B6WM

Notes

1. The external dimensions are different. (KCX: 72mm square ->KCV: 48mm square)
2. The maximum input speed is different. (KCX-B: 20kHz -> KCV: 10kHz)
3. The output current of the power supply for the sensor is different. (KCX: 80mA -> KCV: 60mA)
4. The KCV transistor output cannot be used in positive logic (PNP).
5. The terminal block arrangement and setup method are different between KCX-B and KCV.
6. KCX has no contact output / contact output for the first set value,
. There is also a non-contact output / contact output for the second set value,
. For KCV, the output of the first set value (with prediction output) is non-contact output,
. The output of the second set value is the contact output.

About operation

Operation Mode OUT1 Counting OUT1 Output OUT2 Counting OUT2 Output Replaceability
0 Continuous Holding Continuous Holding Available
1 Continuous Holding Continuous One-shot Unavailable
2 Continuous Holding Reset One-shot Unavailable
3 Continuous One-shot Continuous Holding Available
4 Continuous One-shot Continuous One-shot Unavailable
5 Continuous One-shot Reset One-shot Unavailable
6 Count value is the first set value or less Count value is the second set value or more Unavailable
7 Count value is the first set value or less Count value is the first set value or more and the second set value or less Unavailable
8 Count value is the second set value or more Count value is minus Unavailable
9 Count value is the first set value or more and the second set value or less Count value is the second set value or more Unavailable

Input connection method

counter-23-1

Output connection method

counter-23-2
If the contact output is used for the KCX-B’s first set value output, an external relay is required at the time of replacement.
counter-23-3

If a non-contact output is used for the second set value output of KCX-B, it will be a contact output after replacement.
counter-23-5

Preset value

Both KCX-B / KCV are set with each digit key.

DIP switch setting

Kcounter-22-1
When replacing mode 0 (hold output / count continuation), SW5 of KCV is set to ON.
KCX-B’s Dip SW4 (input / output logic) settings are set in the KCV setup mode.
* The transistor output of KCV cannot be used in positive logic (PNP).

Settings in setup mode

counter-23-4