How Can We Help?
KCV-*T replace
Question
The total counter KCV-*T is continuously used.
I heard that it will be abolished due to model number integration, but which is the alternative model?
Answer
The alternative model is the KCV-*S series.
Please check the following notes when replacing.
Replacement
Model number comparison table
KCV-*T series | KCV-*S series | remarks |
---|---|---|
KCV-4T | KCV-4S | 4-digit AC power supply |
KCV-6T | KCV-6S | 6-digit AC power supply |
KCV-4T-C | KCV-4S-C | 4-digit DC power supply |
KCV-6T-C | KCV-6S-C | 6-digit DC power supply |
Notes
1. Turn off the dip SW3 and set the “Increment mode”.
2. Turn on the dip SW5 and set the output mode to the “Hold output” mode.
3. It is recommended to turn on the dip SW6 and protect the digit key in the setup mode.
4. You can set any number of Preset values and prediction values, but it is recommended to set them to zero.
2. Turn on the dip SW5 and set the output mode to the “Hold output” mode.
3. It is recommended to turn on the dip SW6 and protect the digit key in the setup mode.
4. You can set any number of Preset values and prediction values, but it is recommended to set them to zero.
Inquiry
technical support
Click here for inquiries by email
Click here for inquiries by email