KCV Prediction settings
Question
What is the function of KCV prediction setting?
Answer
The prediction setting function of the KCV series is a function that turns on the prediction output at a fixed value before reaching the Preset value.
The prediction set value can be changed to the set state by pressing and holding the RST button for 3 seconds or longer in the setup mode or the operation mode.
For example, In increment mode, if you set the setting value to 1000 and the prediction setting value to 10, the prediction output will turn ON at 1000-10 = 990.
If you change the setting value to 800, the prediction output will turn ON at 790 if the prediction setting value is 10.
By using this function, the same operation as Double Preset function can be obtained.
If the prediction setting value is set to 0 (factory setting), the prediction output will operate in the same way as the Preset output.
Inquiry
Click here for inquiries by email