How Can We Help?
< All Topics
Print

APS-30/31-*T replacement

Question

Question

APS-30-4T (APS-30-2T, APS-31-4T, APS-31-7T) has failed.
I heard that it has already been discontinued, but is it possible to replace the current product APS-30-4N (APS-30-2N, APS-31-7N)?
If not, what are the alternatives?

Reply

Answer

APS-**-*T series is a DC voltage output type.
This type is DC12V level positive logic operation and has no current switching capability.
On the other hand, APS-**-*N has the same shape, but the output format is NPN open collector output and the specifications are different, so it cannot be replaced.
Although it is not a fully compatible product, APS*-**GK-E2 with PNP open collector output may be used.
If the input resistance of the input device is high, the input may remain ON even if the sensor is OFF.
Click here for more details.

Discontinued products Alternatives Alternatives
Model Diameter Operating
distance
Model Diameter Operating
distance
Model Operating
distance
Remark
APS-30-2T M12 2mm APS5-12GK-E2 M12 5mm
APS-30-4T 4mm APS-13-4T 4mm Square Type
DC Voltage
APS-31-4T M22 4mm
APS-31-7T M22 7mm APS10-18GK-E2 M18 10mm APS-13-4T 4mm Square Type
DC Voltage

Since the case shape and operating distance are different, please check the mounting condition.

Inquiry