DirectLOGIC 405 Series
The DL405 product line packs a lot of power for its size and price. It has the widest variety of I/O modules and configurations of all our PLCs.
-Two kinds of CPU are available
-Module addition:up to 8-slot
-Maximum I/O points:2,048 points
-Program memory:31.5K/Data memory:15.3K
-Communication port:4 port
-PID control:Up to 16 built-in loops
Specification
- AC/DC discrete input/output, up to 64 points per module
- 10 amp relay out
- 12-bit and 16-bit analog inputs and outputs
- Thermocouple and RTD inputs
- Data communications, including serial and Ethernet modules
- Counter input
- Remote I/O master and slave modules
- Ethernet I/O master and slave modules
- New high-speed counter module
- 16 PID loops built in, up to 96 with option modules
Catalog
Technical manual, Software, CAD data
Troubleshooting
Information of Model Numbers
Self-powered CPU Module
Model Numbers | Overview |
---|---|
D4-454 | 【Power Source Type】AC 【Memory】 31.5 K (Built-in)/ 【Maximum input/output】 1,024 points 【Data Register】15.3 K |
D4-454DC-1 | 【Power Source Type】DC 【Memory】 31.5 K (Built-in)/ 【Maximum input/output】 1,024 points 【Data Register】15.3 K |
Base Unit
Model Numbers | Overview |
---|---|
D4-04B-1 | 【Number of Slots】4 【Base Extension Functions】Available |
D4-06B-1 | 【Number of Slots】6 【Base Extension Functions】Available |
D4-08B-1 | 【Number of Slots】8 【Base Extension Functions】Available |
Base Expansion Power Supply Unit
Model Numbers | Overview |
---|---|
D4-EX | 【Power Source Type】AC 【Functions】 Local base expansion unit. NOTE:The base expansion cable (D4-EXCBL-1 or D4-EXCBL-2) is required. |
D4-EXDC | 【Power Source Type】DC 【Functions】 Local base expansion unit. NOTE:The base expansion cable (D4-EXCBL-1 or D4-EXCBL-2) is required. |
Base Expansion Cable
Model Numbers | Overview |
---|---|
D4-EXCBL-1 | Cable length:1 m |
D4-EXCBL-2 | Cable length:0.5m |
Extension IO Module Input Module
Model Numbers | Overview |
---|---|
D4-08ND3S | 【Input】Points:8 Function:24 to 48 V DC Sync/source |
D4-16ND2 | 【Input】Points:16 Function:12 to 24 V DC Source |
D4-16ND2F | 【Input】Points:16 Function:12 to 24 V DC Source |
D4-32ND3-1 | 【Input】Points:32 Function:24 V DC Sync/source Click here for information on cables and terminal blocks. |
D4-64ND2 | 【Input】Points:64 Function:20 to 28 V DC Source Click here for information on cables and terminal blocks. |
D4-08NA | 【Input】Points:8 Function:100 to 200 V AC |
D4-16NA | 【Input】Points:16 Function:100 V AC |
Extension IO Module Output Module
Model Numbers | Overview |
---|---|
F4-08TD1S | 【Output】Points:8 Function:24 to 150 V DC Sync |
D4-16TD1 | 【Output】Points:16 Function:5 to 24 V DC Sync |
D4-16TD2 | 【Output】Points:16 Function:5 to 24 V DC Source |
D4-32TD1 | 【Output】Points:32 Function:5 to 24 V DC Sync Click here for information on cables and terminal blocks. |
D4-32TD2 | 【Output】Points:32 Function:12 to 24 V DC Source Click here for information on cables and terminal blocks. |
D4-64TD1 | 【Output】Points:32 Function:12 to 24 V DC Source Click here for information on cables and terminal blocks. |
D4-08TA | 【Output】Points:8 Function:18 to 220 V AC |
D4-16TA | 【Output】Points:16 Function:18 to 220 V AC |
D4-08TR | 【Output】Points:8 Function:Relay 2 A |
F4-08TRS-1 | 【Output】Points:8 Function:Relay 10 A |
F4-08TRS-2 | 【Output】Points:8 Function:Relay 5 A |
D4-16TR | 【Output】Points:16 Function:Relay 1 A |
Extension IO Module Analog Input Module
Model Numbers | Overview |
---|---|
F4-04AD | 【Analog input】Points:4 Functions: 0 to 5 V/-5 V to +5 V/V/ 1 to 5 V/0 to 10 V/ -10 V to +10 V/ 4 to 20 mA/0 to 20 mA |
F4-04ADS | 【Analog input】Points:4 Functions: 0 to 5 V/0 to 10 V/ 1 to 5 V/-5 V to +5 V/ -10 V to +10 V/ 0 to 20 mA/4 to 20 mA |
F4-08AD | 【Analog input】Points:8 Functions: 4 to 20 mA/1 to 5 V/ 0 to 20 mA/0 to 5 V/ 0 to 10 V/-5 V to +5 V/ -10 V to +10 V |
F4-16AD-1 | 【Analog input】Points:16 Functions:4 to 20 mA |
F4-16AD-2 | 【Analog input】Points:16 Functions:0 to 5 V/0 to 10 V |
F4-08THM | 【Analog input】Points:8 Functions:Thermocouple/Voltage |
F4-08RTD | 【Analog input】Points:8 Functions:Resistance thermometer bulb |
Extension IO Module Analog Output Module
Model Numbers | Overview |
---|---|
F4-04DA-1 | 【Analog output】Points:4 Function:4 to 20 mA |
F4-04DA-2 | 【Analog output】Points:4 Function: 0 to 5 V/0 to 10 V/ -5 V to +5 V/-10 V to +10 V |
F4-08DA-1 | 【Analog output】Points:8 Function:4 to 20 mA |
F4-08DA-2 | 【Analog output】Points:8 Function:0 to 5 V/0 to 10 V |
F4-16DA-1 | 【Analog output】Points:16 Function:4 to 20 mA |
F4-16DA-2 | 【Analog output】Points:16 Function:0 to 5 V/0 to 10 V |
F4-04DAS-1 | 【Analog output】Points:4 Function:4 to 20 mA Source |
F4-04DAS-2 | 【Analog output】Points:4 Function:0 to 5 V/0 to 10 V |
Extension IO Module Special Module
Model Numbers | Overview |
---|---|
D4-RM | Serial remote I/O master |
D4-RS | Remote I/O slave. Built-in 100/200 V power supply |
D4-RSDC | Remote I/O slave. Built-in 24 V DC power supply |
H4-ERM100 | Ethernet remote master 10/100 BASE-T/TX |
H4-ECOM100 | Ethernet communication 10/100 BASE-T/TX |
D4-DCM | Serial communication (2 ports) |
F4-16PID | PID coprocessor module |
F4-4LTC | 4-loop temperature controller |
H4-CTRIO | High speed counter input/output |
Associated Equipment Accessories/Maintenance Product
Model Numbers | Overview |
---|---|
D4-FILL | Dummy slot |
Associated Equipment Peripheral Device
Model Numbers | Overview |
---|---|
PC-DSOFT5 | Programmer software for computer |
FA-ISOCON | RS232 → RS422/RS485 converter |
Associated Equipment Cable / Connector for program
Model Numbers | Overview |
---|---|
S-15CNJ | Conversion connector cable between PLC port (modular) and S-15JP/S-30JG-T (D-sub1 5-pin) |
S-9CNS1 | Conversion connector between DOS/V and Z-20JP |
S-15CNP1 | Conversion connector between Z-20JP and D4 series programmer port (D-sub 15-pin) |
S-25CNP1 | Conversion connector between Z-20JP and D4 series general-purpose port (D-sub 25-pin), between Z-20JP and host link (D-sub 25-pin) |
Z-20JP | Programmer connection cable 2 m, modular jack on both ends |
Associated Equipment Maintenance Product
Model Numbers | Overview |
---|---|
D3-D4-BAT | CPU memory backup battery |
Information of Discontinued Model Numbers
Model Numbers | Successor Model | Information |
---|---|---|
U-23RM | ||
U-05S | ||
U-03RS | ||
U-01GF,U-01KF,U-01KI,U-03PM,U-03RM,U-03RS-AD1,U-04RM | ||
U-05T-H | Similar Products:U-05T | |
U-25N-H | Similar Products:U-25N | |
U-25T-H | Similar Products:U-25T | |
U-30JTB,U-14ABM,U-16DAC-1,U-11DN,D4-02DA | ||
D4-04B,D4-14B | D4-04B-1 | |
D4-06B,D4-14B | D4-06B-1 | |
D4-08B,D4-18B | D4-08B-1 | |
D4-16NA-1 | ||
D4-470,D4-470-P800 | ||
D4-HPP , D4-HPP-1 , S-01P-EX , S-01P2-EX , S-15JP , S-30JP | ||
D4-PULS,D4-PULS-1,D4-RMSM,D4-RS-FW,D4-SM-FW | ||
D4-04AD , U-01AD , U-01AD-1 | F4-04AD | |
U-8ADC-1 | F4-08AD | |
D4-IOCVR,D4-IO32R,D4-IO32S | ||
U-01DA | ||
D4-SS-106,D4-SS-16N,D4-SS-16T,D4-SS-88 | ||
U-01PM2 | ||
D4-16SIM,D4-SM | ||
U-04BJ | Similar Products:U-04B | |
U-06BJ | Similar Products:U-06B | |
U-08BJ | Similar Products:U-08B | |
U-38T | Similar Products:U-18T | |
U-38N | Similar Products:U-08N | |
U-01NI,G-15M | ||
H4-ECOM | H4-ECOM100 | |
H4-ECOM-F,H4-EBC,H4-EBC-F | ||
H4-ERM | H4-ERM100 | |
H4-ERM-F | ||
U-01EW-C | Similar Products:U-01EW | |
D4-08TD1 | Similar Products:D4-16TD1 | |
D4-MC-BAT | ||
U-01Z | Similar Products:H4-CTRIO | |
D4-RMA-1 , D4-RMA-2 , D4-RNB , D4-EE-2 , G-**M | Sales of the G-25M will end as soon as stock runs out. Please consider upgrading to the D4-454, which does not require a memory cartridge. |
|
SU-5, SU-5E,SU-5M,SU-6,SU-6B,SU-6M,SU-6H,D4-425,D4-430,D4-435,D4-440,D4-450 | D4-454 | |
SU-5-C, SU-5E-C,SU-5M-C,SU-6-C,SU-6B-C,SU-6M-C,D4-440DC-1,D4-450DC-1 | D4-454DC-1 | |
D4-440DC-2,D4-450DC-2 | Similar Products:D4-454DC-1 | |
U-4ADC-2 | F4-02DA-1 , F4-02DA-2 | |
S-30JG-T | Can be substituted with a combination of S-9CNS1, Z-20JP, S-15CNP1 | |
S-30JD-T | Can be substituted with a combination of S-9CNS1, Z-20JP, S-25CNP1 | |
TF-32D , TF-32DL , P-C5255J-** , P-C5256J-** , U-**JT . U-**JH | Click here for information on cables and terminal blocks. |
Contact
フォームが表示されるまでしばらくお待ち下さい。
恐れ入りますが、しばらくお待ちいただいてもフォームが表示されない場合は、こちらまでお問い合わせください。